PLS analysis on structural images
mwen
Posted on 07/04/13 11:02:40
Number of posts: 2
mwen posts:

Hi

   Is it possible to run PLS analysis (e.g., mean center PLS) on structural images (e..g, FLAIR images)? If so, any particular steps that need to be taken? Thanks.

 

Ming-Ching

Replies:

Untitled Post

I'm Online
nlobaugh
Posted on 07/04/13 11:07:10
Number of posts: 229
nlobaugh replies:

Hi Ming-ching

 

no.. that should not be done. 

In the same way that the intensity values in a T1-weighted image are "meaningless" from an analysis perspective - FLAIR signal intensities are also "meaningless".  When we segment T1-w images, we convert the signal intensities into GM probability (etc), which then makes it possible to calclate statistics at the voxel level..

your T1/T2 maps are calculated relaxation times, so they are also suitable for voxel-based analysis.

nancy